Detailed Product Description
On line UPS
Uninterruptible Power Supply
High frequency on line UPS 1-3Kva
LED Display
| | High frequency On line UPS | HP9110/9111 1-3KVA | | Applications | | Servers,Data-Center,Cirtical network devices,Sensitive equip - | ment,Telecom.... | | KEY FEATURES | | True on-line double conversion technology with advanced microprpcessor control | | Wide input voltage | | Zero transfer time | | Protection against all types of power problems | | Set test while start of the ups | | Site wiring fault warning | On-battery power-on function | | Smart RS232 communication interface | | | | | | | | | | | |
|
| |
TECHNICAL SPECIFICATIONS
| Model | | HP9110E/9111C 1KT | HP9110E/9111C 2KT | HP9110E/9111C 3KT | HP9110E/9111C 1KT -XL | HP9110E/9111C 2KT -XL | HP9110E/9111C 3KT-XL | | Capacity | VA/W | 1KVA/0.7KW | 2KVA/1.4KW | 3KVA/2.1KW | 1KVA/0.7KW | 2KVA/1.4KW | 3KVA/2.1KW | | Input | Nominal Voltage | 110/115/120VAC or 220/230/240VAC | | Voltage Range | 180-300VAC | | Frequency Range | 50Hz;46-54Hz:60Hz:56-64Hz | | Phase | Single phase | | Power Factor | >0.97 | | Connection | IEC320-10A inlet | IEC320-10A inlet | IEC320-16A inlet | IEC320-10A inlet | IEC320-10A inlet | IEC320-16A inlet | | Output | Voltage | 110/115/120×1±2%VAC 220/230/240×1±2%VAC | | Frequency | Synchronization range(line mode);50 or 60Hz×1±0.2%(Battery mode) | | Phase | Single phase | | Wave Form | Sine Wave | | Power Factor | 0.7 or 0.8 optional | | Voltage Distortion | 3% | 4% | 4% | 3% | 4% | 4% | | Overload Capability | 110%-150% for 30 sec.,≥150% for 200 ms | | Current Crest Radio | 31 | | Connections | IEC320*4 | IEC320*6 | IEC320*3&Terminal bolock | IEC320*4 | IEC320*6 | IEC320*3&Terminal bolock | | Battery&charge | Type | Sealed,Maintenance free,Lead-acid | | Nominal DC to Voltage | | | | 36VDC | 96VDC | 96VDC | | Quantity | 3 pieces | 8 pieces | 8 pieces | Depends on the requested back-up time | | Back-up time(full load) | 5 min | 9 min | 5min | Depends on the capacity of the external battery bank | | Recharge Time | 5 hrs to 90% of capacity | Depends on the capacity of the external battery bank | | Automatic Transfer | On overload and UPS failure | | Before UPS power-on | Default ''ON' user adjustable to 'YES' | | Voltage Range | 40-132VAC (Default),user adjustable within 40-143VAC or 80-264VAC (Default),user adjustable within 80-286VAC | | Transfer tine | AC to DC Zero | Inverter to Bypass 4 ms (Typical) | | Indicators | UG/LED display | Load level / Battery / lever, Battery, Utility power, Inverter, Bypass,Overload, Fault | | UX/LCD display | UPS status, I/P & O/P voltage & frequency, Battery voltage, Battery capacity, Loading, Temperature, History record | | Audible alarm | | Bypass, On battery mode, Battery low, Overload, Fault | | Acoustic noise | At 1 meter distance | 45 dB | 50 dB | 50 dB | 45 dB | 50 dB | 50 dB | | Communications | DB-9 Port | PS-232 Serial interface | | Intelligent Slot | Options:SNMP Card, AS400 Card or Winpower CMC / (usb port) | | Environment | Operating Temperature | 0-40 | | Operatint Humidity | 20-90% non-condensing | | Weight | Net(Kg) | 13 | 31.5 | 32 | 7 | 13.5 | 14 | | Dimensions(package) | W ×D ×H (mm) | 240×495×335 | 335×590×480 | 355×590×480 | 240×495×335 | 335×590×480 | 335×590×480 |
|
The series of HP9110E is the UG series before,the series of HP9111C is the UX series before